Green Certified Products

Panasonic Exhaust Ventilation Fan; Whisper Ceiling DC, FV-0511VQ1, FV-115VQ1, FV-0511VQL1, FV1115VQL1, FV-20VQ3, FV-30VQ3

Panasonic Exhaust Ventilation Fan; Whisper Ceiling DC, FV-0511VQ1, FV-115VQ1, FV-0511VQL1, FV1115VQL1, FV-20VQ3, FV-30VQ3

Product Information:

WhisperCeiling® DC™ Precision Spot Ventilation Fan with built-in Pick-A-Flow™ speed selector switch allow you to select your required airflow (50-80-110 CFM). WhisperCeiling® DC™ features an ECM Motor with SmartFlow® technology and a Flex-Z Fast installation bracket, and lighted models incorporate one 10W dimmable LED chip panel. WhisperCeiling® DC™ can be used to comply with the latest codes and standards.

Certifications:

2015 NGBS
Practice # Practice Points Available Additional Conditions of Use to Earn Points
902.1.4(1) Exhaust fans are ENERGY STAR®, as applicable. 6 points maximum awarded. 2 None. 2 points per fan.

Manufacturer's Comments: WhisperCeiling® DC are ENERGY STAR certified exhaust fans.

902.1.4(2) ENERGY STAR or equivalent fans operating at or below 1 sone are installed. 3 points awarded per fan; 12 points max. 3 None. 3 points per fan.

Manufacturer's Comments: WhisperCeiling® DC are ENERGY STAR certified and operate under one sone.

902.2.1

One of the following whole building ventilation systems is implemented and is in accordance with the specifications of Appendix B.

Points must be claimed in 902.2.1 to claim points in 902.2.2.

3-6 System is implemented in accordance with Appendix B. An explanation of the operation and importance of the ventilation system is included in the operation or homeowner manuals. 3 points for exhaust or supply fans; 6 points for balanced system. Mandatory when maximum air infiltration is less than 5ACH50.

Manufacturer's Comments: Whisper Ceiling DC is ready for continuous operation.

2020 NGBS
Practice # Practice Points Available Additional Conditions of Use to Earn Points
13.107.7 Exhaust systems are in accordance with Chapter 5 of the ICC IMC or ASHRAE 62.1. Mandatory. Mandatory System is installed in non-residential space.

Manufacturer's Comments: Whisper Ceiling DC features a setting timer that is in accordance with ASHRAE 62.1.

13.107.8.1 Ventilation is provided to non-residential spaces in accordance with Chapter 4 of the ICC IMC or ASHRAE 62.1. Mandatory. Mandatory System is installed in non-residential space.

Manufacturer's Comments: Whisper Ceiling DC features a setting timer that is in accordance with ASHRAE 62.1.

902.1.4(1) ENERGY STAR or equivalent fans are installed. 2 points awarded per fan; 12 points max. 2 None. 2 points per fan.

Manufacturer's Comments: WhisperCeiling® DC are ENERGY STAR certified exhaust fans.

902.1.4(2) ENERGY STAR or equivalent fans operating at or below 1 sone are installed. 3 points awarded per fan; 12 points max. 3 None. 3 points per fan.

Manufacturer's Comments: WhisperCeiling® DC are ENERGY STAR certified and operate under one sone.

902.1.6 Ventilation systems are implemented in accordance with the specifications of ASHRAE 62.1. An explanation of the operation and importance of the ventilation system is building owner manual. 3 points available. 3 System is installed in multifamily common areas. System is implemented in accordance with ASHRAE 62.2-2010 Section 4. An explanation of the operation and importance of the ventilation system is included in the operation or homeowner manuals.

Manufacturer's Comments: Whisper Ceiling DC meets ASHRAE 62.2.

902.2.1(1) Balanced exhaust and supply fans are installed in accordance with manufacturer’s guidelines. An explanation of the operation and importance of the ventilation system is included in the homeowner or building owner manual. 6 points available. 3 System is implemented in accordance with ASHRAE 62.2-2010 Section 4. An explanation of the operation and importance of the ventilation system is included in the operation or homeowner manuals. Labels are appropriately labeled. Mandatory when maximum air infiltration is less than 5ACH50.

Manufacturer's Comments: Whisper Ceiling DC is ready for continuous operation.

902.2.1(2) Balanced exhaust and supply fans with supply intakes located in accordance with the manufacturer’s guidelines are installed. an explanation of the operation and importance of the ventilation system is included in the homeowner or building owner manual. 6 points available. 6 System is implemented in accordance with ASHRAE 62.2-2010 Section 4. An explanation of the operation and importance of the ventilation system is included in the operation or homeowner manuals. Fans are positioned to not introduce polluted air back into the building.

Manufacturer's Comments: Whisper Ceiling DC is designed to be part of a whole-building balanced ventilation system.

Terms of Use | Privacy Policy

© 2025. Home Innovation Research Labs. All rights reserved. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Website Design & Development by JET Advertising.