Chapter 7 Interpretation: 2020 NGBS Section 703.1.2 Building Envelope Leakage
Published Tuesday, June 9, 2026
Home Innovation has determined that 2020 NGBS projects pursuing the Chapter 7 Prescriptive Path may use the alternative building envelope air leakage testing metrics and methodologies introduced in the 2021 IECC Sections R402.4.1.2 and R402.4.1.3. Specifically, dwelling units or homes 1,500 square feet or smaller may demonstrate compliance using a maximum leakage rate of 0.30 CFM50/ft² (1.5 L/s/m²) of enclosure area based on weighted-average unguarded compartmentalization testing, in lieu of the ACH50 limits required by the 2018 IECC. This interpretation recognizes that ACH50 disproportionately penalizes smaller, high-density housing due to their lower volume-to-envelope ratios, despite strong air sealing performance. By allowing the 2021 IECC testing option, the NGBS maintains rigorous energy performance expectations while providing a more equitable compliance pathway for small homes and multifamily dwelling units. This interpretation was originally effective October 27, 2023, and was revised on June 1, 2026.
Download the Detailed Interpretation